IEC 61784-2:2010

Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3

OVERVIEW

IEC 61784-2:2010 specifies performance indicators supporting classification schemes for Real-Time Ethernet (RTE) requirements; profiles and related network components based on ISO/IEC 8802-3, IEC 61158 series, and IEC 61784-1; RTE solutions that are able to run in parallel with ISO/IEC 8802-3-based applications. These communication profiles are called Real-Time Ethernet communication profiles. This second edition cancels and replaces the first edition published in 2007 and constitutes a technical revision. The main changes with respect to the previous edition are:

- update of the dated references to the IEC 61158 series, to IEC 61784-1, to the IEC 61784-3 series, to the IEC 61784-5 series and to IEC 61918 throughout the document;

- update of selection tables for CPF 2, CPF 3, CPF 11 and CPF 14;

- addition of a new profile CP 11/2 in 12.3;

- addition of a new profile CP 14/3 in subclause 15.5;

- addition of a new Communication Profile Family - CPF 17;

- new subclause 3.3.12 (CPF 17 symbols);

- new Clause 18 for CPF 17 with one profile;

- addition of a new Communication Profile Family - CPF 18;

- new subclause 3.3.13 (CPF 18 symbols);

- new Clause 19 for CPF 18 with one profile;

- specification changes for CPF3;

- update of the requirements for all conformance classes;

- added precise timing requirements for IP;

- updated timing requirements for IO devices;

- added precise timing requirements for PTCP;

- increasing the amount of synchronized devices in line;

- integrating the fast startup as additional feature.

This bilingual version published in 2011-12, corresponds to the English version published in 2010-07.

COMMENTS

-

PRODUCT DETAILS

Status Revised
Edition 2010
No. of Pages 475
ICS Classification 35.240.50 IT applications in industry
35.100.20 Data link layer
Committee TC 65/SC 65C
Available for Purchase For sale in Singapore only
Adoption IEC : 0