ISO 8873-1:2006
Rigid cellular plastics — Spray-applied polyurethane foam for thermal insulation — Part 1: Material specifications
OVERVIEW
ISO 8873-1:2006 specifies minimum requirements and test methods for spray-applied polyurethane rigid cellular plastic, used as a thermal insulation for both building, whether applied on a building site or in a prefabrication (manufacturing) facility, and non-building applications. The material is also known as in-situ thermal insulation.
The spray-applied polyurethane rigid cellular plastic thermal insulation is not to be used when the continuous service temperature of the substrate is outside the range of -60 °C to +80 °C.
The test methods used to determine the material properties provide a means of comparing different cellular plastic thermal insulations. They are intended for use in specifications, product evaluations and quality control. They are not intended to predict end-use product performance.
COMMENTS
-
PRODUCT DETAILS
| Status | Current |
|---|---|
| Edition | 2006 |
| No. of Pages | 9 |
| ICS Classification | 83.100 Cellular materials |
| Committee | ISO/TC 61/SC 10 |
| Available for Purchase | For sale in Singapore only |
| Adoption | ISO |